FIREROL FRL-SW-1SU-PH15/30, FRL-SW-3SU-PH15/30

    

                                                             A. Conductor B. Insulation

Application

-Used as power cable and control cable for protected installations inside and outside of rail and transport vehicles, where handling andinstallation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor

Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5

Insulation

Mica tape+LSZH elastomeric compound as defined in EN 50264-1 (EI 101 to EI 104)

Electrical & Mechanical Properties

Nominal Voltage 0.6/1 kV or 1.8/3 kV
Maximum Conductor Temperature 90°C (fixed installation)
Minimum Permissible Ambient Temperature -25°C/-40°C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general

EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index
EN 50200:2000 Resistance to fire of unprotected small cable for use in emergency circuits.4 classifications are defined: PH 15,30, 60, or 90(15,30,60, or 90mins).

FRL-SW-1SU-PH15/30 0.6/1 kV

Nominal
Cross-Sectional
Area

Conductor
Diameter
(a)

Min. Mean
Thickness
of Insulation

Overall
Diameter

Weight

Maximum Conductor Resistance

Insulation Resistance

min

max

20°C

20°C

90°C

mm2

mm

mm

mm

mm

kg/km

Ω/km

MΩ x km

MΩ x km

1.0

1.25

0.8

2.8

3.2

18

20

65

0.65

1.5

1.5

0.8

3.0

3.5

20

13.7

55

0.55

2.5

1.95

0.8

3.4

3.9

30

8.21

50

0.5

4.0

2.5

0.8

3.9

4.6

50

5.09

40

0.4

6.0

3.0

0.9

4.6

5.4

70

3.39

35

0.35

10

3.9

1.1

5.8

6.8

130

1.95

30

0.3

16

5.0

1.1

7.2

8.5

170

1.24

30

0.3

25

6.4

1.3

8.6

10.0

260

0.795

30

0.3

35

7.7

1.3

10.2

11.5

350

0.565

25

0.25

50

9.2

1.5

11.6

13.5

500

0.393

25

0.25

70

11.0

1.5

13.3

15.5

690

0.277

20

0.2

95

12.5

1.6

14.9

17.4

910

0.210

20

0.2

120

14.2

1.6

16.5

19.3

1120

0.164

20

0.2

150

15.8

1.9

18.5

21.7

1430

0.132

15

0.15

185

17.5

1.9

20.1

23.6

1720

0.108

15

0.15

240

20.1

2.1

22.9

25.8

2290

0.0817

15

0.15

300

22.5

2.2

25.4

29.7

2810

0.0654

10

0.1

400

25.8

2.3

28.7

33.6

3690

0.0495

10

0.1

FRL-SW-3SU-PH15/30 1.8/3 kV

Nominal
Cross-Sectional
Area

Conductor
Diameter
(a)

Min. Mean
Thickness
of Insulation

Overall
Diameter

Weight

Maximum Conductor Resistance

Insulation Resistance

min

max

20°C

20°C

90°C

mm2

mm

mm

mm

mm

kg/km

Ω/km

MΩ x km

MΩ x km

1.5

1.5

2.5

6.2

7.3

70

13.70

120

1.2

2.5

1.95

2.5

6.6

7.8

90

8.21

100

1.0

4.0

2.5

2.5

7.1

8.4

110

5.09

90

0.9

6.0

3.0

2.5

7.6

8.9

130

3.39

80

0.8

10

3.9

2.5

8.4

9.9

190

1.95

65

0.65

16

5.0

2.5

9.5

11.1

250

1.24

55

0.55

25

6.4

2.5

10.8

12.7

330

0.795

45

0.45

35

7.7

2.5

12.0

14.1

430

0.565

40

0.4

50

9.2

2.5

13.4

15.7

570

0.393

35

0.35

70

11.0

2.5

15.1

17.7

760

0.277

30

0.3

95

12.5

2.7

16.9

19.8

980

0.210

30

0.3

120

14.2

2.7

18.5

21.7

1210

0.164

25

0.25

150

15.8

2.7

20.0

23.4

1500

0.132

20

0.2

185

17.5

2.7

21.6

25.3

1800

0.1080

20

0.2

240

20.1

2.7

24.1

28.2

2360

0.0817

20

0.2

300

22.5

2.7

26.3

30.8

2840

0.0654

15

0.15

400

25.8

2.9

29.8

34.9

3800

0.0495

15

0.15